The Study Design feature of Nalvera.AI groups your scans by patient, measures every outlined structure, follows it over time, and compares patient groups.
- Create a study
- Add scans with their dates
- Send scans to an AI model
- Measure every structure
- Compare and report
How do I measure organ volumes from a CT scan?
Add the scan to a study and send it to a segmentation model such as TotalSegmentator. Nalvera.AI then measures every outlined structure in your browser and lists its volume and Hounsfield values in one table that you can export. The CT segmentation guide shows which model outlines which structures.
How do I get SUV values from a PET scan?
Attach the PET scan to its CT or MRI scan in a study that has a segmentation. Each structure then gets its SUVmean, SUVmax, and SUVpeak.
Can I overlay a PET or SPECT scan on a CT or MRI?
Yes. The Fusion Viewer shows a PET or SPECT scan over its CT or MRI scan, and you can align the two in your browser.
What can I measure on a SPECT scan?
Attach the SPECT scan to its CT scan in a study that has a segmentation. Each structure then gets its volume and its counts: the total, the mean, and the maximum. A calibrated SPECT scan also gives the activity in the structure, its share of the injected activity, and SUV.
How do I follow a tumour or organ over time?
Enter each scan's date. Trends then charts a structure's volume or SUV over time, for one patient or for all patients together. Volume charts add the percentage change and the doubling time.
How do I compare a measurement between patient groups?
Add a patient field such as treatment arm and choose it under Compare groups. Each structure then shows its summary statistics per group, and two groups are compared with a statistical test.
What is measured
| Measure | On |
|---|---|
| Volume | Every structure, on CT and MRI |
| Hounsfield values | Every structure on CT |
| SUVmean, SUVmax, SUVpeak | Structures with a PET scan attached |
| Counts and activity | Structures with a SPECT scan attached |
| Diameter | Lesions |
How the values are calculated
Volume is the number of voxels in a structure times the size of one voxel. SUV follows the DICOM standard and QIBA's vendor-neutral calculation, with the injected dose corrected for decay.
Questions
What does measuring cost?
Nothing. Measurements, charts, group comparisons and study reports use no credits. The AI task that makes the segmentation uses credits or a free AI run.
Can I measure a segmentation I made myself?
Yes. Attach your own segmentation to a scan in the study, or outline a structure with clicks in the Interactive Studio. Both are measured like an AI result.
Can I test whether an imaging measurement predicts an outcome?
Yes, for an outcome with two classes, such as responder or non-responder. Compare groups draws the ROC curve of a chosen measurement, with its AUC. The result is exploratory.
How do I see which patients still need a scan or a result?
The Cohort tab shows all patients and their scans in one grid and marks where a scan or a result is missing.
What can I download for my paper?
A study report, a table of all measurements, and the segmentations of each scan.
Research use only. Nalvera.AI is not a medical device.